Panasonic LP-V Series Operation And Maintenance Manual page 102

Laser marker
Hide thumbs Also See for LP-V Series:
Table of Contents

Advertisement

1. Set the counter.
1.
Press [FUNCTION], and press [COUNTER].
Here the condition is set to Counter No. 0.
Reference
• The counter is settable up to 4 per file (0 to 3). Other than this setting, the setting for "common counter" (4 to 7) that are
common to all files are available. For details, refer to "4-13-3 Common Counter" (P.235).
2.
Set "1" to [Curr] (current value).
Set "1" to [Init] (initial value).
Set "1000" to [End] (end value).
Set "1" to [Step].
Select "TRIG" (TRIGGER) for [Source] (Count
Source).