Radiation Information [LP-V/LP-W Series]

⿎ Marking Laser (Class 4)
Class 4 laser refers to "Laser products for which intrabeam viewing and skin exposure is hazardous and for which the
viewing of diffuse reflections may be hazardous. These lasers also often represent a fire hazard."
Model Name
Wavelength
Laser Medium
Max. Output *1
Mode of Operation
Pulse Cycle
Pulse Width *2
Class
NOHD *3
MPE *4
NHZ represents the area where the amount of beam irradiance or radiant
exposure exceeds the maximum permissible exposure to eyes. It is equal of
NHZ
NOHD at a maximum.
NHZ varies depending on the reflectance or surface condition of works.
Please calculate it based on the actual working environment.
*1 : The maximum output power means the maximum value of output that can be output from a laser oscillator itself.
Refer to "1-3 Specification" (P.36) for details of average output.
*2 : The pulse width means the available output range from the laser oscillator itself.
*3 : "NOHD" means the distance that the area where the amount of beam irradiance or radiant exposure becomes equal
to the maximum permissible exposure to eyes.
*4 : MPE in this table is a value calculated with exposure time set to 10 seconds.
⿎ Guide Laser and Pointer (Class 2)
The laser classified into the Class 2 refers to "Laser products that emit visible radiation in the wavelength range from 400
nm to 700 nm that are safe for momentary exposures but can be hazardous for deliberate staring into the beam."
Model Name
Wavelength
Laser Medium
Max. Output *1
Mode of Operation
Class
*1 : Sum of the guide laser and pointer values.
LP-V10U
Yb:FIBER
40 W
Pulsed
10 μs to 50 μs
1 ns to 1000 ns
35.8 m
LP-V/LP-W series
Semiconductor Laser
CW (continuous wave)
ME-LP400V-OP-6
LP-V15U
1060nm
(continuous wave)
4
65.9 m
2
50 W/m
655nm
1mW
2
LP-W052U
Remarks
Invisible beam
7.5 W
CW
Nominal ocular
21 m
hazard distance
Maximum
Permissible
Exposure
Nominal hazard
zone
Remarks