⿎ Common
1
2
3
Common Setting Item
1
Proc. Cond. No. (Processing Condition No.) :
Specifies up to 8 processing condition per one registered file.
Setting Range
2
X/Y Offset :
Shifts the marking position to the X or Y direction.
Setting Range
3
Rotation Angle :
Rotates the object to the rotation direction around the origin.
Setting Range
4
Laser Power Correction :
Scan Speed Correction :
Laser Pulse Cycle Correction (Only LP-V series) :
Correction of the processing elements in the selected processing condition No. for the laser power / scan speed /
laser pulse cycle set at laser setting.
If the correction rate is set to 0%, the marking image is displayed in gray and marking is not executed.
Setting Range of Laser Power Correction
Setting Range of Scan Speed Correction
Setting Range of Laser Pulse Cycle Correction
5
Area No. :
Displayed when marking on-the-fly is set in "Trigger setting".
It indicates the order of the marking field for the concatenated marking to flying object.
Setting Range
4
0 to 7
-45.000 to +45.000 mm
-55.000 to +55.000 mm
-80.000 to +80.000 mm
-27.500 to +27.500 mm
-180.00 to +180.00 degree
0 to 15
ME-LP400V-OP-6
5
(LP-V10)
(LP-430 / LP-420 / LP-410)
(LP-435 / LP-425 / LP-V15)
(LP-431 / LP-421 / LP-411 / LP-W052)
0 to 200%
5 to 500%
50 to 200%