⿎ Step & Repeat Fine-Adjustment
In the Step & Repeat marking, when the marking position or power setting of some patterns are adjusted separately, set
this fine-adjustment conditions.
1
2
4
5
8
Description
1
Adjustment item:
Select the adjustment target form the followings.
• Single:
Provides adjustment to the marking position for a pattern specified by the target row and the target column.
• Mark OFF:
Skips the marking of a pattern specified at "Row and Column".
• All Col. (All Column) / All Row:
Provides adjustment to all marking positions for patterns included in the columns/rows from that specified at
"Column" or "Row" to the last.
• 1 Col. (1 Column) / 1 Row:
Provides adjustment to all marking positions for patterns included in the column/row specified.
Reference
• The pattern to which "Marking OFF" is specified is not displayed on the operator adjustment screen and on the image
display screen under the adjustment of character condition.
2
Row (Target Row):
3
Column (Target Column):
Specifies the intended row / column for the fine adjustment for Step & Repeat.
Setting Range
Reference
• Max. number of settable patterns is 1000.
• The fine tuning is enabled only for the specified rows and columns.
178
3
9
10
1 to 100
6
7
11
ME-LP400V-OP-6