Pressure Terminal for RRH-2WB Frame Grounding
As for the pressure terminal or the cable, the UL certified products or equivalent
should be used.
Ex) Manufacturer-Panduit
2
4 mm
Pressure Terminal: LCD10-14AF-L
When connecting the pressure terminal to a cable, remove the cable sheath
where the pressure terminal is connected, and then push the cable all the way to
the end of the cable lead-in part.
Check the position of the coaxial cable through the inspection window of the
pressure terminal before compressing it with a compressor.
© SAMSUNG Electronics Co., Ltd.