Parameters; Parameter List - Mitsubishi Electric MR-D30 Instruction Manual

Melservo series general-purpose ac servo functional safety unit
Hide thumbs Also See for MR-D30:
Table of Contents

Advertisement

5. PARAMETERS

5. PARAMETERS
CAUTION

5.1 Parameter list

Never make a drastic adjustment or change to the parameter values as doing so
will make the operation unstable.
Do not change the parameter settings as described below. Doing so may cause
an unexpected condition such as failing to start up the servo amplifier.
Changing the values of the parameters for manufacturer setting.
A value out of the range is set.
Changing the fixed values in the digits of a parameter.
POINT
For parameters of servo amplifiers, refer to each servo amplifier instruction
manual.
POINT
The parameter whose symbol is preceded by * is enabled with the following
conditions:
*: After setting the parameter, cycle the power or reset the controller.
**: After setting the parameter, cycle the power.
Abbreviations of operation modes indicate the followings.
Servo motor: Standard (semi closed loop system) use of the servo motor
Servo motor with functional safety: Standard (semi closed loop system) use of
Full.: Fully closed loop system use of the servo motor or servo motor with
functional safety
Lin.: Linear servo motor use
DD: Direct drive (DD) motor use
the servo motor with functional safety
5 - 1