FLEXANALOG ITEMS
Address
FlexAnalog name
9622
PMU 1 I0 Angle
A
9623
PMU 1 Freq
9625
PMU 1 df dt
9626
PMU 1 Conf Ch
9631
PMU 2 Va Mag
9633
PMU 2 Va Angle
9634
PMU 2 Vb Mag
9636
PMU 2 Vb Angle
9637
PMU 2 Vc Mag
9639
PMU 2 Vc Angle
9640
PMU 2 Vx Mag
9642
PMU 2 Vx Angle
9643
PMU 2 V1 Mag
9645
PMU 2 V1 Angle
9646
PMU 2 V2 Mag
9648
PMU 2 V2 Angle
9649
PMU 2 V0 Mag
9651
PMU 2 V0 Angle
9652
PMU 2 Ia Mag
9654
PMU 2 Ia Angle
9655
PMU 2 Ib Mag
9657
PMU 2 Ib Angle
9658
PMU 2 Ic Mag
9660
PMU 2 Ic Angle
9661
PMU 2 Ig Mag
9663
PMU 2 Ig Angle
9664
PMU 2 I1 Mag
9666
PMU 2 I1 Angle
9667
PMU 2 I2 Mag
9669
PMU 2 I2 Angle
9670
PMU 2 I0 Mag
9672
PMU 2 I0 Angle
9673
PMU 2 Freq
9675
PMU 2 df dt
9676
PMU 2 Conf Ch
9681
PMU 3 Va Mag
9683
PMU 3 Va Angle
9684
PMU 3 Vb Mag
9686
PMU 3 Vb Angle
9687
PMU 3 Vc Mag
9689
PMU 3 Vc Angle
9690
PMU 3 Vx Mag
9692
PMU 3 Vx Angle
9693
PMU 3 V1 Mag
9695
PMU 3 V1 Angle
9696
PMU 3 V2 Mag
9698
PMU 3 V2 Angle
A-22
Units
Description
Degrees
Phasor measurement unit 1 zero-sequence current angle
Hz
Phasor measurement unit 1 frequency
Hz/s
Phasor measurement unit 1 rate of change of frequency
---
Phasor measurement unit 1 configuration change counter
Volts
Phasor measurement unit 2 phase A voltage magnitude
Degrees
Phasor measurement unit 2 phase A voltage angle
Volts
Phasor measurement unit 2 phase B voltage magnitude
Degrees
Phasor measurement unit 2 phase B voltage angle
Volts
Phasor measurement unit 2 phase C voltage magnitude
Degrees
Phasor measurement unit 2 phase C voltage angle
Volts
Phasor measurement unit 2 auxiliary voltage magnitude
Degrees
Phasor measurement unit 2 auxiliary voltage angle
Volts
Phasor measurement unit 2 positive-sequence voltage magnitude
Degrees
Phasor measurement unit 2 positive-sequence voltage angle
Volts
Phasor measurement unit 2 negative-sequence voltage magnitude
Degrees
Phasor measurement unit 2 negative-sequence voltage angle
Volts
Phasor measurement unit 2 zero-sequence voltage magnitude
Degrees
Phasor measurement unit 2 zero-sequence voltage angle
Amps
Phasor measurement unit 2 phase A current magnitude
Degrees
Phasor measurement unit 2 phase A current angle
Amps
Phasor measurement unit 2 phase B current magnitude
Degrees
Phasor measurement unit 2 phase B current angle
Amps
Phasor measurement unit 2 phase C current magnitude
Degrees
Phasor measurement unit 2 phase C current angle
Amps
Phasor measurement unit 2 ground current magnitude
Degrees
Phasor measurement unit 2 ground current angle
Amps
Phasor measurement unit 2 positive-sequence current magnitude
Degrees
Phasor measurement unit 2 positive-sequence current angle
Amps
Phasor measurement unit 2 negative-sequence current magnitude
Degrees
Phasor measurement unit 2 negative-sequence current angle
Amps
Phasor measurement unit 2 zero-sequence current magnitude
Degrees
Phasor measurement unit 2 zero-sequence current angle
Hz
Phasor measurement unit 2 frequency
Hz/s
Phasor measurement unit 2 rate of change of frequency
---
Phasor measurement unit 2 configuration change counter
Volts
Phasor measurement unit 3 phase A voltage magnitude
Degrees
Phasor measurement unit 3 phase A voltage angle
Volts
Phasor measurement unit 3 phase B voltage magnitude
Degrees
Phasor measurement unit 3 phase B voltage angle
Volts
Phasor measurement unit 3 phase C voltage magnitude
Degrees
Phasor measurement unit 3 phase C voltage angle
Volts
Phasor measurement unit 3 auxiliary voltage magnitude
Degrees
Phasor measurement unit 3 auxiliary voltage angle
Volts
Phasor measurement unit 3 positive-sequence voltage magnitude
Degrees
Phasor measurement unit 3 positive-sequence voltage angle
Volts
Phasor measurement unit 3 negative-sequence voltage magnitude
Degrees
Phasor measurement unit 3 negative-sequence voltage angle
N60 NETWORK STABILITY AND SYNCHROPHASOR MEASUREMENT SYSTEM – INSTRUCTION MANUAL