CHAPTER 5: SETTINGS
Operand type
State
RxGOOSE Boolean
On
Virtual Input
On
Virtual Output
On
The following table lists the operands available for the relay. The operands can be viewed online by entering the IP address
of the relay in a web browser and accessing the Device Information Menu.
Table 5-25: N60 FlexLogic operands
Operand type
Operand syntax
ANNUNCIATOR
ANY ANCTR ABNORMAL
Graphical front panel
ANY ANCTR ALARMED
CONTROL
CONTROL PUSHBTN 1 ON
PUSHBUTTONS
CONTROL PUSHBTN 2 ON
Enhanced and
CONTROL PUSHBTN 3 ON
standard front panels
CONTROL PUSHBTN 4 ON
CONTROL PUSHBTN 5 ON
CONTROL PUSHBTN 6 ON
CONTROL PUSHBTN 7 ON
CYBERSENTRY
ROLE ADMIN ACT
ROLE SUPERVISOR ACT
ROLE ENGINEER ACT
ROLE OPERATOR ACT
ROLE OBSERVER ACT
AUTHENTICATION FAIL
UNAUTH FW ATTEMPT
UNAUTH SETTING WRITE
DIRECT DEVICES
DIRECT DEVICE 1On
DIRECT DEVICE 16On
DIRECT DEVICE 1Off
DIRECT DEVICE 16Off
DIRECT INPUT/
DIR IO CH1 CRC ALARM
OUTPUT CHANNEL
MONITORING
DIR IO CH2 CRC ALARM
DIR IO CH1 UNRET ALM
DIR IO CH2 UNRET ALM
ELEMENT:
8BIT COMP 1 PKP
Eight-bit comparator
8BIT COMP 1 DPO
8BIT COMP 1 OP
8BIT COMP 1 BIT 0
8BIT COMP 1 BIT 1
8BIT COMP 1 BIT 2
8BIT COMP 1 BIT 3
8BIT COMP 1 BIT 4
8BIT COMP 1 BIT 5
8BIT COMP 1 BIT 6
8BIT COMP 1 BIT 7
8BIT COMP 2 to 6
N60 NETWORK STABILITY AND SYNCHROPHASOR MEASUREMENT SYSTEM – INSTRUCTION MANUAL
Example of format
Characteristics
[Input Is '1' (= ON) if...]
RxGOOSE Boolean 1 On
The RxGOOSE Boolean is presently in the ON state
Virt Ip 1 On
The virtual input is presently in the ON state
Virt Op 1 On
The virtual output is presently in the set state (that is,
evaluation of the equation that produces this virtual output
results in a "1")
Operand description
On for one second when any annunciator window state changes from
normal to abnormal
On while any annunciator window state is abnormal
Control pushbutton 1 is being pressed
Control pushbutton 2 is being pressed
Control pushbutton 3 is being pressed
Control pushbutton 4 is being pressed
Control pushbutton 5 is being pressed
Control pushbutton 6 is being pressed
Control pushbutton 7 is being pressed
Administrator role is active and is set to true when that is the case
Supervisor role is active and is set to true when that is the case
Engineer role is active and is set to true when that is the case
Operator role is active and is set to true when that is the case
Observer role is active and is set to true when that is the case
Operand set for Failed Authentication self-test and alarm
Operand set for firmware lock self-test and alarm
Operand set for settings lock self-test and alarm
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
The rate of direct input messages received on channel 1 and failing the CRC
exceeded the user-specified level
The rate of direct input messages received on channel 2 and failing the CRC
exceeded the user-specified level
The rate of returned direct input/output messages on channel 1 exceeded
the user-specified level (ring configurations only)
The rate of returned direct input/output messages on channel 2 exceeded
the user-specified level (ring configurations only)
Comparator 1 has picked up
Comparator 1 has dropped out
Comparator 1 has operated
Bit 0 of comparator 1 asserted (the least significant bit)
Bit 1 of comparator 1 asserted
Bit 2 of comparator 1 asserted
Bit 3 of comparator 1 asserted
Bit 4 of comparator 1 asserted
Bit 5 of comparator 1 asserted
Bit 6 of comparator 1 asserted (the most significant bit)
Sign bit of comparator 1 asserted (asserted for negative values; de-asserted
for positive values)
Same set of operands as shown for 8 BIT COMP 1
FLEXLOGIC