Embedded fieldbus

Overview

The ACS550 can be set up to accept control from an external system using standard
serial communication protocols. When using serial communication, the ACS550 can
either:
• receive all of its control information from the fieldbus, or
• be controlled from some combination of fieldbus control and other available
control locations, such as digital or analog inputs and the control panel.
Connect using either:
• standard embedded fieldbus (EFB) at
• fieldbus adapter (FBA) module mounted
Two basic serial communications configurations are available:
• embedded fieldbus (EFB) – Using the RS485 interface at terminals X1:28...32 on
the control board, a control system can communicate with the drive using the
Modbus® protocol. (For protocol and profile descriptions, see sections
protocol technical data
chapter.)
• fieldbus adapter (FBA) – See chapter

Control interface

In general, the basic control interface between Modbus and the drive consists of:
• Output words
– Control Word
– Reference1
– Reference2
• Input words
– Status Word
– Actual value 1
– Actual value 2
terminals X1:28...32
in slot 2 (option Rxxx).
and
Fieldbus controller
Fieldbus
ABB control profiles technical data
Fieldbus adapter
Other devices
Modbus
later in this
on page 221.