ACS550 User's Manual
Code Description
35 =
– Energize relay based on input from fieldbus communication.
COMM
• Fieldbus writes binary code in parameter 0134 that can energize relay 1...relay 6 according to the following:
Par. 0134
Binary
0
000000
1
000001
2
000010
3
000011
4
000100
5...62
63
111111
• 0 = De-energize relay, 1 = Energize relay.
36 =
(-1) – Energize relay based on input from fieldbus communication.
COMM
• Fieldbus writes binary code in parameter 0134 that can energize relay 1...relay 6 according to the following:
Par. 0134 Binary
0
000000
1
000001
2
000010
3
000011
4
000100
5...62
63
111111
• 0 = De-energize relay, 1 = Energize relay.
37 =
1 – Energize relay when Timed Function 1 is active. See
TIMED FUNC
38...40 =
TIMED FUNC
41 =
– Energize relay when cooling fan counter is triggered. See
MNT TRIG FAN
42 =
– Energize relay when revolutions counter is triggered. See
MNT TRIG REV
43 =
– Energize relay when run time counter is triggered. See
MNT TRIG RUN
44 =
MNT TRIG MWH
46 =
– Energize relay when a start delay is active.
START DELAY
47 =
– Energize relay when a user load curve fault or alarm occurs.
USER LOAD C
52 =
– Energize relay when the jogging function is active.
JOG ACTIVE
1402 RELAY OUTPUT 2
Defines the event or condition that activates relay 2 – what relay output 2 means.
• See 1401
RELAY OUTPUT
1403 RELAY OUTPUT 3
Defines the event or condition that activates relay 3 – what relay output 3 means.
• See 1401
RELAY OUTPUT
1404 RO 1 ON DELAY
Defines the switch-on delay for relay 1.
• On / off delays are ignored when relay output 1401 is set to PFC.
1405 RO 1 OFF DELAY
Defines the switch-off delay for relay 1.
• On / off delays are ignored when relay output 1401 is set to PFC.
1406 RO 2 ON DELAY
Defines the switch-on delay for relay 2.
• See
1
RO
ON DELAY
1407 RO 2 OFF DELAY
Defines the switch-off delay for relay 2.
• See
1
RO
OFF DELAY
1408 RO 3 ON DELAY
Defines the switch-on delay for relay 3.
• See
1
RO
ON DELAY
RO6 RO5 RO4 RO3 RO2 RO1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
...
...
...
...
1
1
1
RO6
RO5 RO4 RO3 RO2 RO1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
...
...
...
...
0
0
0
2...4 – Energize relay when Timed Function 2...4 is active. See
– Energize relay when MWh counter is triggered. See
1.
1.
.
.
.
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
...
...
...
1
1
1
1
1
1
1
1
0
1
0
1
1
0
0
0
1
1
...
...
...
0
0
0
Group 36: TIMED
Group 29: MAINTENANCE
Control event
Relay status
FUNCTIONS.
1 above.
TIMED FUNC
Group 29: MAINTENANCE
Group 29: MAINTENANCE
Group 29: MAINTENANCE
TRIG.
1404
1405
ON DELAY
117
TRIG.
TRIG.
TRIG.
OFF DELAY
Parameters