ABB ACS550 User Manual page 132

Hide thumbs Also See for ACS550:
Table of Contents

Advertisement

132
Code Description
2208 EMERG DEC TIME
Sets the deceleration time for maximum frequency to zero for an emergency.
• See parameter 2109
• Ramp is linear.
2209 RAMP INPUT 0
Defines control for forcing the ramp input to 0.
0 =
– Not selected.
NOT SEL
1 =
1 – Defines digital input
DI
• Activating the digital input forces ramp input to 0. Ramp output will ramp to 0 according to the currently used ramp
time, after which it will stay at 0.
• De-activating the digital input: ramp resumes normal operation.
2...6 =
2...
6 – Defines digital input
DI
DI
• See
1 above.
DI
7 =
– Defines bit 13 of the Command Word 1 as the control for forcing the ramp input to 0.
COMM
• The Command Word is supplied through fieldbus communication.
• The Command Word is parameter 0301.
-1 =
1(
) – Defines an inverted digital input
DI
INV
• De-activating the digital input forces ramp input to 0.
• Activating the digital input: ramp resumes normal operation.
-2...-6 =
2(
)...
DI
INV
DI
generator input to 0.
• See
1(
) above.
DI
INV
Parameters
.
EMERG STOP SEL
1 as the control for forcing the ramp input to 0.
DI
2...
6 as the control for forcing the ramp input to 0.
DI
DI
6(
) – Defines an inverted digital input
INV
1 as the control for forcing the ramp input to 0.
DI
2...
6 as the control for forcing the ramp function
DI
DI
ACS550 User's Manual