Issue 5.0
Related Features
Central Office Calls, Answering
Central Office Calls, Placing
Direct Inward System Access (DISA)
Multiple Trunk Types
Warning Tone for Long Conversation
Guide to Feature Programming
Program
Number
14-01-14
14-01-15
20-06-01
20-13-02
20-13-03
20-21-03
1 - 644
Program Name
Basic Trunk Data Setup – Long
Conversation Cutoff
Basic Trunk Data Setup – Long
Conversation Alarm Before Cut
Off
Class of Service for Extensions
Class of Service Options
(Supplementary Service) – Long
Conversation Cutoff (Incoming)
Class of Service Options
(Supplementary Service) – Long
Conversation Cutoff
(Outgoing)
System Options for Long
Conversation – Long
Conversation Cutoff for
Incoming Call
Description/Comments
Enable (1) or disable (0) a trunk
ability to disconnect incoming and
outgoing central office calls
automatically.
Enable (1) or disable (0) the Long
Conversation Alarm for each
trunk.
Assign a Class of Service (1~15)
to extensions.
Turns Off (0) or On (1) an
extension ability to use Long
Conversation Cutoff for incoming
calls.
Turns Off (0) or On (1) an
extension ability to use Long
Conversation Cutoff for outgoing
calls.
Enter the time the system waits
before disconnecting incoming
trunks (0~64800 seconds).
UNIVERGE SV8100
Assigned Data
0 = Disable
1 = Enable
(default = 0)
0 = Disable
1 = Enable
(default = 0)
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
All extension port =
Class 1
0 = Off
1 = On
(default = 0 for
COS 1~15)
0 = Off
1 = On
(default = 0 for
COS 1~15)
0~64800 (seconds)
(default = 0)