12.7.1
SET circuit
12.7.2
Access and
UNSET switching
L240/BS
Late return disarming feature (internal set):
–
The area is internally set (e.g. via the keypad L240/PT).
–
By the once-off insertion of a valid chip key or entry of a 6-digit
keypad code, access is enabled and the area defined is unset.
For external setting, the area must be in ready to set state (door locked,
etc.).
Depending on the programming of the Evaluation Module L240/BS (see
chapter 12) it can also be set:
1.
With keypad code:
Enter a valid 6-digit keypad code (with the respective authorization)
and press button "PROG".
2.
With chip key:
Insert a valid chip key (with the respective authorization) twice and
retract it again (max. 4 sec. between both insertions).
3.
In VdS class C: alternately with keypad code or chip key.
If the area switches to SET, a three second long continuous tone sounds
as a positive acknowledgement.
If the area does NOT switch to SET (e.g. no valid setting authorization or
the area was not ready to switch), a three second long intermittent tone
will sound to indicate a negative acknowledgement.
If the area is not ready to set, a negative acknowledgement occurs after
an external setting attempt. After entry of the user PIN code on the
Keypad L240/PT the criteria (reason for prevention of setting) is
displayed.
Depending on the programming of the Evaluation Module L240/BS (VdS
class, see chapter 12), unsetting is also possible:
92