ABB L240 Series Installation, Commissioning & Operation page 49

Security technology knx-intrusion alarm system
Hide thumbs Also See for L240 Series:
Table of Contents

Advertisement

Configuration and Programming by the Engineer
The apartment (area 2/main area) can only be set if the office (area 1/sub-
area) has been set. This ensures that setting of the office area cannot be
forgotten when leaving the building. On returning home the apartment must
be unset and only then can the office be unset.
Deleting the dependencies of the areas is undertaken in the respective area
menus (enter with button "0" or Off).
Assignment of area-relevant messages
If different areas have been introduced, there is often a demand to
differentiate between messages and signals from the individual areas and to
transfer them to a control centre. In the following sub-menus, different
messages (e.g. external setting area 2) to one of the transistor outputs 11-18
can be programmed for this purpose. Accordingly, one channel of a
transmission device can be used. The outputs can also be used for other
control functions.
For each area the following signals are available:
 External alarm
 Internal alarm
 External set
 Reset (pulse)
 Personal attack
 Fault
 Setting (arming) acknowledgement
 Ready to set
 Internal alarm
 Unset
 Fire alarm
Example:
The internal alarm for area 2 should be programmed to transistor output 7.
In menu item "02=Area Opts" area 2 and the sub-menu "10=Int Alm TX"
should be selected:
Area
Number 2
10=Int Alm TX
11=Unset TX
Area-2 Int Alm
TX-7
Area-2 Int Alm
Device-0
Area-2 Int Alm
Invert-Off
Now when there is an internal alarm from area 2, transistor 7 (terminal 17)
will switch.
Press button 2
Press buttons 1 0
Select output 7
Press button 0 (central outputs)
Press button 0 for Off (Invert Off)
49

Advertisement

Table of Contents
loading

Table of Contents