LED yellow
LED green
AM Sens.
Fault
Undervoltage
Anti stealth
Log

13.7 Walk test

13.8 Delete

Bus Motion Detector
LED yellow – on/off
The yellow LED indicates the response of the passive infrared sensors and
further displays of the detector (see chapter 13.3).
LED green – on/off
The green LED indicates the response of the microwave sensors and further
displays of the detector (see chapter 13.3).
AM Sens. – on/off
Increases the sensitivity of the anti-mask monitoring.
Fault – on/off
Transfers detector faults to the Intrusion Alarm Panel and displays them on
the keypads. If this function is deactivated, the state of the detector is
indicated by its own LEDs.
Undervoltage – on/off
Transfers the undervoltage of a detector to the Intrusion Alarm Panel and
displays this on the keypads. If this function is deactivated, the undervoltage
of the detector is indicated via the red LED.
Anti-stealth – on/off
Increases the sensitivity and evaluation of the passive infrared share of the
motion detector and thus detects objects or persons who have assumed the
approximate ambient temperature.
Log – on/off
Activates the alarm log function of the detector. The alarm log is set if the
detector is triggered in the set state and indicates triggering after unset
switching via the red LED. Thus, you can recognise which detector has
triggered an alarm.
The walk test function enables setting of the detection range of the motion
detector. The LEDs are activated even when they have been switched off in
the programming. After the walk test, the LEDs are returned to their previous
state. The alarm log is not deleted in this case.
The reset of the anti-mask monitoring also occurs with the walk test function.
Hereby, the detection range of the detector must be entered and you must
wait until the yellow LED switches off.
Before a motion detector is removed from the XIB bus, it must be deleted
from the keypad.
In the submenu select function
1=Auto Add
2=Add XIB Det.
3=Edit XIB Det.
4=Del XIB Det.
Circuit
Number _ _ _
Cct nn
= Confirm
4
"4=Del XIB
Det.":
Select the corresponding circuit
!
Press button
to acknowledge
100