Menu 02 "Area Opts - ABB L240 Series Installation, Commissioning & Operation

Security technology knx-intrusion alarm system
Hide thumbs Also See for L240 Series:
Table of Contents

Advertisement

Configuration and Programming by the Engineer
8.1.2

Menu 02 "Area Opts"

Engineer-PIN
8 = Edit
01 = System Size
02 = Area Opts
03 = Circuits
04 = Relay
05 = Alarm Times
06 = Keypads
07 = Concs *
08 = User Auth
09 = Text
10 = L240/B/BS*
11 = XS/1.1 KNX *
13 = 2-Conc Tamper *
15 = Defaults
16 = XIB-Detectors
L208/A/R (reserved for future applications):
System Size
OPM-0
Reserved for future applications: Please do not change the number 0.
KNX (EIB) – Interface:
System Size
XS/S1.1 KNX-1
The Interface XS/S 1.1 integrates the Intrusion Alarm Panel L240 into the
EIB/KNX intelligent installation system. Thus, the XIB bus is connected to
the Intrusion Alarm Panel. The Interface XS/S1.1 KNX is activated in this
menu.
The other communication settings are undertaken in menu 11
KNX", see chapter 8.1.1. The settings for the evaluation of the detector
circuits can be found in Menu 03 "Circuits" under Properties of the circuit
types chapter 8.1.3.2.
Menu item "02=Area Opts": In this menu, item areas can be assigned
under another area (formation of sub-areas) and defined area-relevant
messages can be assigned to a transistor output. The formation of main and
sub-areas relates only to the external setting/unsetting operation. An internal
setting/unsetting of the main area is not permissible.
Area
Number _
After entry of the area the sub-menu appears.
01=Master Areas
02=Ext Alarm TX
03=Int Set TX
04=Ext Set TX
05=Reset TX
06=PA TX
07=Fault TX
08=Set Cnfrm TX
09=Rdy Set TX
10=Int Alm TX
11=Unset TX
12=Fire TX
The panel can manage up to four setting areas in total. After assignment of
the bus device to the individual areas, the individual areas operate
independently of each other (sub-areas). Area 1 and 2 can thus be set and
unset separately. This is useful, for example, in a main apartment with a
separate granny flat as the occupants set and unset the system at different
times, or for a commercial property (jewellery store) with residential section.
(0)
(0 or 1)
"XS/S1.1