Installation Instructions

2.1

General explanations

2.2

Wiring

Installation Instructions
All electrical work may only be performed when the system is not live.
The installation and commissioning may only be carried out by
electrical specialists.
The installation locations of the panel and keypads must comply with the
guidelines of the VdS or the VDE 0833. They should be:
within the security area and monitoring area of a detector,
on the interior wall of the building,
not visible to third-parties.
As there are no keypads or displays on the panel, they can be installed in
concealed locations (e.g. in the cellar or in a wall cabinet).
The keypad(s) should be easily accessible for the operator.
The following cable types must be used for wiring the system:
Low-voltage 230 V AC:
Extra-low voltage:
Components for connection
XIB bus device:
Keypads L240/PT
Interface Module L208/V.24
Evaluation Module L240/BS
Detector Circuit Modules /MG2,
L840/MG4
BUS Motion Detector
Magnetic contacts,
Passive glass break sensors:
Combination Signalling Devices
SSF/GB:
The sheath wire of the shield (cable of the detector group,
XIB bus line, ...) must be consistently looped through and attached to the
earthing stud in the panel on the left beside the cable entry.
The shield may not be earthed at any other point on the cable network
(earth loops).
The sequence in which the bus slaves are connected is irrelevant; no spur
lines may be used. Max. length of the bus cable: 800 m.
For connection optimisation, the use of a main distribution board (e.g. MV40
or MV80) is recommended.
NYM 3 x 1.5 mm²
I-Y(St)Y n x 2 x 0.8 mm
Required twin-cores
2
2
6
10