ABB L240 Series Installation, Commissioning & Operation page 15

Security technology knx-intrusion alarm system
Hide thumbs Also See for L240 Series:
Table of Contents

Advertisement

Panel tampert
Comm alarm
Comm fault
Sirens
Strobe
free
Buzzer
Relay 2 (walk test)
Relay 1 (ext. set)
Unset
Intern Alarm
External ready to set
Setting acknowledge
Fault
Ext. unset
Personal attack
Intrusion
2k7
Cct 10, ext. set
Cct 9, tampering
2k7
Cct 8, pers. attack
2k7
Cct 7, lock
Cct 6
2k7
Cct 5
2k7
2k7
Cct 4
Cct 3
2k7
2k7
Cct 2
Cct 1
2k7
Voltage supply
for ext. devices
Installation Instructions
Circuit diagram:
820
820
820
820
820
820
820
820
Continuous alarm
15