Menu 13 "2-Conc Tamper; Menu 15 "Defaults - ABB L240 Series Installation, Commissioning & Operation

Security technology knx-intrusion alarm system
Hide thumbs Also See for L240 Series:
Table of Contents

Advertisement

Configuration and Programming by the Engineer
8.1.12 Menu 13 "2-Conc
Tamper"
Engineer-PIN
8 = Edit
01 = System Size
02 = Area Opts
03 = Circuits
04 = Relay
05 = Alarm Times
06 = Keypads
07 = Concs *
08 = User Auth
09 = Text
10 = L240/B/BS*
11 = XS/1.1 KNX *
13 = 2-Conc Tamper *
15 = Defaults
16 = XIB-Detectors

8.1.13 Menu 15 "Defaults"

Engineer-PIN
8 = Edit
01 = System Size
02 = Area Opts
03 = Circuits
04 = Relay
05 = Alarm Times
06 = Keypads
07 = Concs *
08 = User Auth
09 = Text
10 = L240/B/BS*
11 = XS/1.1 KNX *
13 = 2-Conc Tamper *
15 = Defaults
16 = XIB-Detectors
Inhibit or enable reset:
XS/S1.1 KNX
Reset-On
Inhibit or enable tamper reset (only if reset on):
XS/S1.1 KNX
Tamp.Reset-Off
Enable or inhibit signal at bus voltage failure:
XS/S1.1 KNX
Sig Failure-Off
Type of message with bus voltage failure (only if Signal Failure-Off=On):
XS/S1.1 KNX
Signal-Fault
Menu item "13=2-Conc Tamper": In this menu, the monitoring of the panel
tamper contact for each circuit Detector Circuit Module L240/MG2 is
activated or deactivated. The procedure should be taken from chapter 12 "2-
Circuit Modules L240/MG2".
Menu item "15=Defaults": All the entered texts can be deleted and the
modified user codes can be reset to the default delivery state. The submenu
"4=L240/BS" is only displayed when the Evaluation Module L240/BS is
connected and enables a defined reset (incl. the configuration and the
databases).
2=Text
3=User PINs
4=L240/BS
After selection of the menu item, reset/delete occurs (CAUTION: no further
security query).
Loading defaults
Please Wait ...
(0=Off;1=On)
(0=Off;1=On)
(0=Off;1=On)
(1=Fault; 2=Tamper)