External Actual Temperature; External Actual Temperature 2; Fault, Actual Temperature; Local Actual Temperature - ABB -i-Bus-KNX Millenium Reference Manual

Room temperature controller
Hide thumbs Also See for ABB-i-Bus-KNX Millenium:
Table of Contents

Advertisement

KNX Technical Reference Manual
®
ABB-i-Bus
-KNX Millenium
Pos: 31.11.9 /DinA-4 -- Online/Applikations- / Parameterbeschreibungen -- (KNX)/Kommunikationsobjekte/Objekt-RTR / RTR/Module/Externe Ist-Temperatur @ 41\mod_1422460928926_15.docx @ 329830 @ 3 @ 1
11.5.7

External actual temperature

Number
7
2-byte communication object for reading an external temperature value provided via the KNX
bus.
Pos: 31.11.10 /DinA-4 -- Online/Applikations- / Parameterbeschreibungen -- (KNX)/Kommunikationsobjekte/Objekt-RTR / RTR/Module/Externe Ist-Temperatur 2 @ 41\mod_1422460982185_15.docx @ 329846 @ 3 @ 1
11.5.8

External actual temperature 2

Number
8
2-byte communication object for reading an additional external temperature value provided via
the KNX bus.
Pos: 31.11.11 /DinA-4 -- Online/Applikations- / Parameterbeschreibungen -- (KNX)/Kommunikationsobjekte/Objekt-RTR / RTR/Module/Störung Ist-Temperatur @ 41\mod_1422461044836_15.docx @ 329862 @ 3 @ 1
11.5.9

Fault, actual temperature

Number
9
If one of the parameterized input temperatures is unavailable to the controller for a period longer
than the monitoring time, the controller enters the error mode. The error mode is sent to the bus
as the value 1.
Note
About item 2:
This object must be connected to the "Fault, actual temperature (slave)" object in
order to indicate the error mode.
About item 3:
This object must be connected to the "Fault, actual temperature (slave)" object in
order to indicate the error mode.
Pos: 31.11.12 /DinA-4 -- Online/Applikations- / Parameterbeschreibungen -- (KNX)/Kommunikationsobjekte/Objekt-RTR / RTR/Module/Lokale Ist-Temperatur @ 41\mod_1422461103648_15.docx @ 329878 @ 3 @ 1
11.5.10

Local actual temperature

Number
10
Not visible!
Pos: 31.11.13 /Systemmodule/++++++++++++++ Seitenumbruch +++++++++++++++ @ 41\mod_1422789416992_0.docx @ 333487 @ @ 1
KNX Technical Reference Manual | 1473-1-8681
Name
External actual temperature
Name
External actual temperature 2
Name
1. Fault, actual temperature
2. Fault, actual temperature
(master)
3. Fault, actual temperature
(slave)
Name
Local actual temperature
Description of applications /
Object function
Data type
Input
2-byte floating point
value
Object function
Data type
2-byte floating point
Input
value
Object function
Data type
Output
Switching
Output
Switching
Output
Switching
Object function
Data type
Output
Switching
objects
— 76 —