Threshold Value / Hysteresis - ABB -i-Bus-KNX Millenium Reference Manual

Room temperature controller
Hide thumbs Also See for ABB-i-Bus-KNX Millenium:
Table of Contents

Advertisement

KNX Technical Reference Manual
®
ABB-i-Bus
-KNX Millenium
Min/Max value transducer objects
No.
Object name
0
Output (1 Byte 0..100 %)
0
Output (1 Byte 0..255)
0
Output (2 Byte Float)
0
Output (2 Byte Signed)
0
Output (2 Byte Unsigned)
0
Output (4 Byte Float)
0
Output (4 Byte Signed)
0
Output (4 Byte Unsigned)
1...10
Input 1 [2...10] (1 Byte 0..100 %)
1...10
Input 1 [2...10] (1 Byte 0..255)
1...10
Input 1 [2...10] (2 Byte Float)
1...10
Input 1 [2...10] (2 Byte Signed)
1...10
Input 1 (2 Byte Unsigned)
1...10
Input 1 [2...10] (4 Byte Float)
1...10
Input 1 [2...10] (4 Byte Signed)
1...10
Input 1 [2...10] (4 Byte Unsigned)
Pos: 31.39 /Layout bis 2014-11-11/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/3. Ebene/S - T/Schwellwert / Hysterese @ 41\mod_1422541233092_15.docx @ 331654 @ 2 @ 1
11.8.8

Threshold value / hysteresis

Pos: 31.40 /Layout bis 2014-11-11/Online-Hilfe/Power-Tool/Power-Tool 2/chm-Online-Hilfe/App/SchwellwertHysterese/App. - Schwellwert / Hysterese - DIN-A4 @ 10\mod_1269512775480_15.docx @ 53199 @ @ 1
With the "Threshold value / Hysteresis" application, value telegrams can be received on an input communication
object and compared with threshold values specified in the device.
Predefined values are sent out on the communication "Output" communication object if the upper or lower
thresholds are exceeded. The size of the object can be adjusted for different applications.
The function can be temporarily blocked via an enable object.
If the value of the lower threshold lies above the value for the upper threshold, the function is not executed.
Threshold value / hysteresis objects
No.
Object name
0
Input (1 Byte 0..100 %)
0
Input (1 Byte 0..255)
0
Input (2 Byte Float)
0
Input (2 Byte Signed)
0
Input (2 Byte Unsigned)
0
Input (4 Byte Float)
0
Input (4 Byte Signed)
0
Input (4 Byte Unsigned)
1
Output (1 Bit)
1
Output (1 Byte 0..100 %)
1
Output (1 Byte 0..255)
2
Enable
KNX Technical Reference Manual | 1473-1-8681
Description of applications /
Data type
1 Byte EIS6 / DPT 5.001
1 Byte EIS14 / DPT 5.010
2 Byte EIS5 / DPT 9.xxx
2 Byte EIS10 / DPT 8.001
2 Byte EIS10 / DPT 7.001
4 Byte EIS9 / DPT 14.xxx
4 Byte EIS11 / DPT 13.001
4 Byte EIS11 / DPT 12.001
1 Byte EIS6 / DPT 5.001
1 Byte EIS14 / DPT 5.010
2 Byte EIS5 / DPT 9.xxx
2 Byte EIS10 / DPT 8.001
2 Byte EIS10 / DPT 7.001
4 Byte EIS9 / DPT 14.xxx
4 Byte EIS11 / DPT 13.001
4 Byte EIS11 / DPT 12.001
Data type
1 Byte EIS6 / DPT 5.001
1 Byte EIS14 / DPT 5.010
2 Byte EIS5 / DPT 9.xxx
2 Byte EIS10 / DPT 8.001
2 Byte EIS10 / DPT 7.001
4 Byte EIS9 / DPT 14.xxx
4 Byte EIS11 / DPT 12.001
4 Byte EIS11 / DPT 13.001
1 Bit EIS1 / DPT 1.001
1 Byte EIS6 / DPT 5.001
1 Byte EIS14 / DPT 5.010
1 Bit EIS1 / DPT 1.001
objects
Flags
C, T
C, T
C, T
C, T
C, T
C, T
C, T
C, T
C, W
C, W
C, W
C, W
C, W
C, W
C, W
C, W
Flags
C, W
C, W
C, W
C, W
C, W
C, W
C, W
C, W
C, T
C, T
C, T
C, W
— 101 —