Voice Only Wt4090 Ipl Error Indications; Creating A Splash Screen - Motorola WT4070 Integrator Manual

Wearable terminal
Hide thumbs Also See for WT4070:
Table of Contents

Advertisement

IPL Errors (Continued)
Table 7-4
Error Text
Exceeded max size
Partition is not valid on
this device
Wrong destination code
File type does not
support IPL Auto Select
Non-contiguous record
found
Timed Out - No data
Fail: Buffer Overrun
Partition Table not Valid
Invalid file format

Voice Only WT4090 IPL Error Indications

While downloading if there are any errors all three LEDs blink for three seconds and then turn solid.

Creating a Splash Screen

The source bitmap files used to create the default splash screens for the wearable terminal are supplied with the
DCP for WT40x0c50. These files can be modified using any of the standard windows image editors, allowing
customization for particular customers.
To create a custom splash screen, perform the following steps:
For wearable terminals with monochrome screens, open the Splashmono.bmp file supplied with the DCP for
1.
WT40x0c50 using an image editor.
For wearable terminals with color screens, open the Splashcolor.bmp file supplied with the DCP for
2.
WT40x0c50 using an image editor.
Modify the bitmap file and save.
3.
Create a splash partition using the steps shown in the
4.
Splash Screen Format
5.
Error
Number
-26
The download file is too large to fit into the space allocated for it. Either
make the file smaller or increase the space allocated for it by altering
the partition table.
-27
The downloaded file specifies a partition entry that does not exist on the
device. Only download files that are valid for this device, or change the
partition table so that the new file is valid on the device.
-28
A specific partition was chosen from the Main Menu (not Auto Select)
but the file selected for download was for another partition. Ensure that
the partition selected from the Main Menu matches the file selected for
download.
-29
Monitor, Power Micro and Partition Table cannot be loaded with Auto
Select. Select the appropriate area, and try again.
-30
A Symbol HEX file download was attempted but the HEX file is invalid.
Ensure the file is in Symbol HEX file format.
-31
IPL was waiting for data from the source device but timed out before
receiving any. Check the source device connectivity and retry.
-32
The serial port device could not keep up with incoming data. Retry the
serial download with a lower baud rate.
-33
The size of flash memory is different than that described in the partition
table. Retry the download with the correct partition table file.
-34
The file format is invalid. Only Symbol HEX files are supported by IPL.
Application Deployment 7 - 19
Probable Cause
Building the Image on page
7-9.

Hide quick links: