TROUBLESHOOTING GUIDE
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
Electrical Shock Hazard
PROBLEM
NOTE: Possible Cause/Tests MUST be performed
in the sequence shown for each problem.
WON'T POWER UP.
1. Supply connection. See TEST #1.
2. Check harness connections.
(No response when a
3. User interface assembly. See TEST #5.
cycle button is pressed.)
1. If number display flashes, check to be sure the
door is completely shut, and press and hold
WON'T START CYCLE
down Start for about 1 second.
WHEN START BUTTON
IS PRESSED.
2. See TEST #2.
3. See TEST #6.
1. Check Pause/Cancel button. See TEST #5.
WON'T SHUT OFF
2. User interface assembly. See TEST #5.
WHEN EXPECTED.
3. Moisture Sensor. See TEST #4.
CONTROL WON'T
User interface assembly. See TEST #5.
ACCEPT SELECTIONS.
1. Heater. See TEST #3.
WON'T HEAT.
2. Check harness connections.
3. Check installation.
HEATS IN AIR CYCLE.
Temperature sensor. See TEST #3a.
SHUTS OFF BEFORE
Moisture Sensor. See TEST #4.
CLOTHES ARE DRY.
Figure 2. Component Locations
6-20
WARNING
POSSIBLE CAUSE / TEST