Flame Sensor; High Limit Thermostat - KitchenAid Pro Line KHEV01RSS Technical Education

Front-loading gas and electric dryers
Hide thumbs Also See for Pro Line KHEV01RSS:
Table of Contents

Advertisement

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

FLAME SENSOR

Refer to page 4-10 for the procedure for ac-
cessing the flame sensor.
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
3. Disconnect the wire connectors from the
flame sensor terminals.
4. Set the ohmmeter to the R X 1 scale.
5. Touch the ohmmeter test leads to the flame
sensor terminals. The meter should indicate
a closed circuit (0 Ω).
Terminals
WARNING
Electrical Shock Hazard

HIGH LIMIT THERMOSTAT

Refer to pages 4-8 or 4-10 for the procedure
for accessing the high limit thermostat.
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
3. Disconnect the wire connectors from the
4. Set the ohmmeter to the R X 1 scale.
5. Touch the ohmmeter test leads to the
Flame Sensor
5-9
high limit thermostat terminals.
high limit thermostat terminals. The meter
should indicate a closed circuit (0 Ω).
Terminals
High Limit
Thermostat