Removing The Burner Assembly, Flame Sensor, Thermal Cutoff (Tco), And High Limit Thermostat (Gas Dryers Only) - KitchenAid Pro Line KHEV01RSS Technical Education

Front-loading gas and electric dryers
Hide thumbs Also See for Pro Line KHEV01RSS:
Table of Contents

Advertisement

REMOVING THE BURNER ASSEMBLY,
FLAME SENSOR, THERMAL CUTOFF (TCO),
AND HIGH LIMIT THERMOSTAT (GAS DRYERS ONLY)
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Remove the toe panel from the front of the
dryer (see page 4-6 for the procedure).
4.
To remove the burner assembly:
a) Remove the manifold nut from the burner
assembly.
b) Remove the two T-20 screws from the
burner support bracket, and pull the burn-
er assembly away from the bracket.
Burner Assembly
Burner Bracket Screws
Manifold Nut
4-10
c) Disconnect the following wires from the
burner assembly:
• 2-wire connector from the ignitor.
• 2-wire & 3-wire connectors from the
coil assembly.
Ignitor Connector
Coil Assembly 3-Wire Connector
d) To remove the ignitor from the burner
assembly, loosen the 5/16˝ hex-head
screw, and remove the ignitor from the
mounting bracket.
Ignitor
Screw
Bracket
Coil Assembly
2-Wire Connector