REMOVING THE EXHAUST HIGH LIMIT THERMOSTAT
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug dryer or disconnect power.
2.
Turn off gas supply to dryer.
3.
Remove the top cover from the dryer (see
page 4-2 for the procedure).
4.
Pull the lint filter out of the toe panel as
far as it will go, press down on the release
lever, and remove the filter.
Release Lever
Lint Filter
& THE TEMPERATURE SENSOR
Toe Panel
5.
Open the dryer door.
6.
Remove the four T-20 screws from the top
of the toe panel, then remove the panel
by pulling the top forward, and lifting and
unhooking the bottom from the slots.
7.
Remove the three T-20 screws from the
AC terminal wiring cover (electric models
only) and remove the cover.
8.
Remove the ten T-20 screws from the
rear panel, and remove the panel from the
dryer.
10 Rear
Panel Screws
4-6
4 Screws
Toe Panel
AC Terminal Wiring Cover
Screws
Rear Panel