Gas Dryers; Display Fault/Error Codes - KitchenAid Pro Line KHEV01RSS Technical Education

Front-loading gas and electric dryers
Hide thumbs Also See for Pro Line KHEV01RSS:
Table of Contents

Advertisement

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

DISPLAY FAULT/ERROR CODES

The error codes below would be indicated when

GAS DRYERS

DISPLAY
DESCRIPTION
POWER
PF
FAILURE
TEMPERATURE
E1
SENSOR
OPEN
TEMPERATURE
E2
SENSOR
SHORTED
BLOWER
E3
ROTATION
FAILURE
TUMBLER
E4
ROTATION
FAILURE
DRY RACK
E5
SENSOR
EXHAUST
E6
HIGH LIMIT
FAULT
WARNING
Electrical Shock Hazard
attempting to start a drying cycle, or after acti-
vating the Diagnostic Test mode.
EXPLANATION AND RECOMMENDED
PROCEDURE
PF flashes to indicate that a power failure
occurred while the dryer was running. Press
Start to continue the cycle, or press
Pause/Cancel to clear the display.
Refer to TEST #1.
E1 flashes in the numeric display when the
temperature sensing circuit is open.
Refer to TEST #3a.
E2 flashes in the numeric display when the
temperature sensing circuit is shorted.
Refer to TEST #3a.
If during a cycle the blower rotational speed
drops below 500 rpms, all outputs will be
turned off and error code E3 will be displayed.
Refer to Diagnostics Tests, Diag Test #2.
If during a cycle the tumbler rotational speed
drops to 0, all outputs will be turned off and
error code E4 will be displayed.
Refer to Diagnostics Tests, Diag Test #2.
If during a Dry Rack cycle the signal is lost,
all outputs are turned off and E5 is displayed.
Refer to TEST #8.
If the exhaust temperature goes above 87.7°C
(190°F) all outputs will turn off and E6 will be
displayed.
Refer to TEST #3b.
6-16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro line khgv01rss

Table of Contents