Venting Requirements - KitchenAid Pro Line KHEV01RSS Technical Education

Front-loading gas and electric dryers
Hide thumbs Also See for Pro Line KHEV01RSS:
Table of Contents

Advertisement

Burner input requirements
Elevations above 10,000 ft (3,000 m):
When installed above 10,000 ft (3,000 m)
a 4% reduction of the burner Btu rating
shown on the model/serial number plate is
required for each 1,000 ft (300 m) above
sea level.
Gas supply pressure testing
The dryer must be disconnected from the
gas supply piping system during pressure
testing at pressures greater than 1/2 psi.
Dryer gas pipe
The gas pipe that comes out through the
rear of your dryer has a 3/8˝ male pipe
thread.
A
2- ¹³⁄
"*
16
(7.1 cm)
A. ½" NPT gas supply line
.
B
³⁄
" NPT dryer pipe
8
*NOTE: If the dryer is mounted on a pedes-
tal, the gas pipe height must be an additional
11˝(28 cm) from the floor. For a garage instal-
lation, the gas pipe height must be an addi-
tional 18˝ (46 cm) from the floor.
B
4"
(12.3 cm)

VENTING REQUIREMENTS

WARNING
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions
can result in death or fire.
WARNING: To reduce the risk of fire, this dry-
er must be exhausted outdoors.
IMPORTANT: Observe all governing codes
and ordinances.
The dryer exhaust must not be connected into
any gas vent, chimney, wall, ceiling, or a con-
cealed space of a building.
If using an existing vent system
Clean lint from the entire length of the sys-
tem and make sure exhaust hood is not
plugged with lint.
Replace any plastic or metal foil vent with
rigid metal vent.
Review Vent system chart. Modify existing
vent system if necessary to achieve the
best drying performance.
2-15
Fire Hazard