If this is a new vent system
Vent Material
•
Use a heavy metal vent. Do not use plastic
or metal foil vent.
•
4˝ (10.2 cm) heavy metal exhaust vent
and clamps must be used. DURASAFE
venting products are recommended.
4" (10.2 cm) heavy metal exhaust vent
DURASAFE
vent products can be pur-
™
chased from your dealer or by calling
Whirlpool Parts and Accessories.
Rigid metal vent
•
For best drying performance, rigid metal
vents are recommended.
•
Rigid metal vent is recommended to pre-
vent crushing and kinking.
Flexible metal vent
•
Flexible metal vents are acceptable only if
accessible for cleaning and the total length
does not exceed 8 ft (2.4 m).
•
Flexible metal vent must be fully extended
and supported when the dryer is in its final
position.
•
Remove excess flexible metal vent to avoid
sagging and kinking that may result in re-
duced airflow and poor performance.
•
Do not install flexible metal vent in enclosed
walls, ceilings or floors.
Elbows
45° elbows provide better airflow than 90° el-
bows
Good
4"
10.2 cm
Better
Clamps
•
Use clamps to seal all joints.
•
Exhaust vent must not be connected or se-
cured with screws or other fastening devic-
es that extend into the interior of the duct.
Do not use duct tape.
™
Exhaust
Recommended hood styles are shown here.
The angled hood style (shown here) is ac-
ceptable.
(10.2 cm)
•
An exhaust hood should cap the vent to
prevent rodents and insects from entering
the home.
•
Exhaust hood must be at least 12˝ (30.5 cm)
from the ground or any object that may be
in the path of the exhaust (such as flowers,
rocks or bushes, snow line, etc.).
•
Do not use an exhaust hood with a mag-
netic latch.
Improper venting can cause moisture and
lint to collect indoors, which may result
in:
•
Moisture damage to woodwork, furniture,
paint, wallpaper, carpets, etc.
•
Housecleaning problems and health prob-
lems.
2-16
Clamp
B
A
4"
(10.2 cm)
4"
(10.2 cm)
A. Louvered hood style
B. Box hood style
4"
2½"
(6.4 cm)