Cisco 6509 - Catalyst Chassis Switch Installation Manual page 241

Installation guide
Table of Contents

Advertisement

Appendix A
Power Supply Specifications
Table A-13 2700 W Power Supply Specifications (continued)
Specification
DC-input current (per DC input)
Power supply output (AC supply)
Power supply output (DC supply)
DC input terminal block
Output holdup time
Heat Dissipation
OL-5781-04
2700 W AC-Input and DC-Input Power Supplies
Description
43 A @ –40.5 VDC
37 A @ –48 VDC
29 A @ –60 VDC
100/120 VAC operation
15 A @ +1.5 VDC
2.5 A @ +3.3 VDC
27.49 A @ +50 VDC
200/240 VAC operation
15 A @ +1.5 VDC
2.5 A @ +3.3 VDC
55.61 A @ +50 VDC
One DC input operation
15 A @ +1.5 VDC
5 A @ +3.3 VDC
27.49 A @ +50 VDC
Two DC inputs operation
15 A @ +1.5 VDC
5 A @ +3.3 VDC
55.61 A @ +50 VDC
Accepts 2–14 AWG copper conductors. Actual size of
the wire needed is determined by the installer or local
electrician. Terminal block material rated at 150°C.
20 ms minimum (AC-input power supply)
4 ms (DC-input power supply)
11,238 BTU/hour (approx.) AC-input power
supply
11,968 BTU/hour (approx.) DC-input power
supply
Catalyst 6500 Series Switches Installation Guide