Installing the Rack-Mount Kit
The rack must have sufficient vertical clearance to insert the chassis. The chassis heights are as
follows:
Chassis height is sometimes measured in rack units (RU).
Note
The chassis should be empty when you install it in the rack.
Caution
If the rack is on wheels, ensure that the brakes are engaged or that the rack is otherwise stabilized.
Caution
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special
Warning
precautions to ensure that the system remains stable. The following guidelines are provided to
ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest
component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in
the rack.
To maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain
Note
a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis
air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air
exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can
cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front
to back, the chassis may be placed side-by-side.
Catalyst 6500 Series Switches Installation Guide
3-4
Catalyst 6503 switch—7 inches (17.8 cm) (4 RU)
Catalyst 6503-E switch—7 inches (17.8 cm) (4 RU)
Catalyst 6504-E switch—8.7 inches (22.1 cm) (5 RU)
Catalyst 6506 switch—20.1 inches (51.1 cm) (12 RU)
Catalyst 6506-E switch—20.1 inches (51.1 cm) (12 RU)
Catalyst 6509 switch—25.2 inches (64.0 cm) (15 RU)
Catalyst 6509-E switch—25.2 inches (64.0 cm) (15 RU)
Catalyst 6509-NEB switch—33.3 inches (84.6 cm) (20 RU)
Catalyst 6509-NEB-A switch—36.65 inches (93.1 cm) (21 RU)
Catalyst 6513 switch—33.3 inches (84.6 cm) (20 RU)