Table 2
Error and Event Messages (continued)
Message
DOT11-2-RADIO_HW_RESET: Radio
subsystem is under going hardware reset
to recover from problem
DOT11-3-BADSTATE: [mac-address]
[chars] [chars] -> [chars]
DOT11-3-RADIO_OVER_
TEMPERATURE: Interface [interface]
Radio over temperature
DOT11-3-RADIO_IF_LO: Interface
[interface] Radio cannot lock IF freq
DOT11-3-RADIO_RF_LO: Interface
[interface] Radio cannot lock RF freq
DOT11-3-RF_LOOPBACK_FAILURE:
Interface [interface] Radio failed to pass
RF loopback test
DOT11-3-TX_PWR_OUT_OF_
RANGE: Interface [interface] Radio Tx
power control out of range
DOT11-4-MAXERTRIES: Packet to
client [mac] reached max retries,
remove the client
DOT11-6-ASSOC: Interface [interface],
Station [char] [mac] Associated
DOT11-6-ADD: Interface [interface],
Station [mac] Associated to Parent
[mac]
DOT11-6-DISASSOC: Interface
[interface], Deauthenticating Station
[mac] [char]
DOT11-6-ROAMED: Station
[mac-address] Roamed to [mac-address]
Unzip Messages
Explanation
Radio must be reset due to problem.
802.11 association and management uses
a table-driven state machine to keep track
and transition an Association through
various states. A state transition occurs
when an Association receives one of
many possible events. When this error
occurs, it means that an Association
received an event that it did not expect
while in this state.
The WMIC detected that the unit has
exceeded the radio operating
temperature.
The unit cannot lock the intermediate
frequency.
The unit cannot lock the radio frequency. None.
Radio loopback test failed at startup time. None.
The unit has detected that the radio
transmit power cannot be locked within
the operating range.
A packet sent to the client has not been
successfully delivered many times, and
the max retries limit has been reached.
The client is deleted from the association
table.
A station associated to a bridge.
A station associated to a bridge.
A station disassociated from a bridge.
A station has roamed to a new bridge.
Cisco 3200 Series Wireless MIC Software Configuration Guide
Error and Event Messages
Recommended Action
None.
The system can continue but may lose
the Association that generates this
error. Copy the message exactly as it
appears and report it to your technical
service representative.
Investigate and take steps to cool the
unit.
None.
None.
None.
None.
None.
None.
None.