Configuring Summer Time (Daylight Saving Time) - Cisco C3201FESMIC-TP= - 3201 Fast EN Switch Mobile Interface Card Expansion Module Software Configuration Manual

Wireless mic
Table of Contents

Advertisement

Managing the System Time and Date

Configuring Summer Time (Daylight Saving Time)

To configure daylight saving time in areas where it starts and ends on a particular day of the week each
year, follow these steps, beginning in privileged EXEC mode:
Command
Step 1
configure terminal
Step 2
clock summer-time zone recurring
[week day month hh:mm week day month
hh:mm [offset]]
Step 3
end
Step 4
show running-config
Step 5
copy running-config startup-config
The first part of the clock summer-time command specifies when daylight savings time begins, and the
second part specifies when it ends. All times are relative to the local time zone. The start time is relative
to standard time. The end time is relative to daylight savings time. If the starting month is after the ending
month, the system assumes that you are in the southern hemisphere.
This example shows how to specify that summer time starts on the first Sunday in April at 02:00 and
ends on the last Sunday in October at 02:00:
bridge(config)# clock summer-time PDT recurring 1 Sunday April 2:00 last Sunday October
2:00
Cisco 3200 Series Wireless MIC Software Configuration Guide
46
Purpose
Enters global configuration mode.
Configures summer time to start and end on the specified days every year.
Summer time is disabled by default. If you specify clock summer-time
zone recurring without parameters, the summer time rules default to the
United States rules.
For zone, specify the name of the time zone (for example, PDT) to be
displayed when summer time is in effect.
(Optional) For week, specify the week of the month (1 to 5 or last).
(Optional) For day, specify the day of the week (Sunday, Monday...).
(Optional) For month, specify the month (January, February...).
(Optional) For hh:mm, specify the time (24-hour format) in hours and
minutes.
(Optional) For offset, specify the number of minutes to add during
summer time. The default is 60.
Returns to privileged EXEC mode.
Verifies your entries.
(Optional) Saves your entries in the configuration file.