Parameter list

The following shows the parameters that can be set for the NZ2FT-PN.
Web server
The following are parameters to be set on the Web server. ( Page 74 Parameter setting)
Parameters other than the following are set by GX Configurator-PN of the RJ71PN92, so do not set them by the Web server.
Item
Description
Webserver via Ethernet
Set whether to enable or disable the access to the Web server via the Ethernet port.
The NZ2FT-PN must be reset after the setting.
HTTPS setting
Set this parameter when encrypting the communications with the Web server. (
Page 67 HTTPS setting)
• HTTP & HTTPS concurrent operation: HTTP and HTTPS communications are
possible.
• only HTTPS; no HTTP: Only HTTPS communications are possible.
Configure the settings while communications are not being performed with the RJ71PN92. Use any of the following methods
to stop communications.
• Turn off the CPU module and RJ71PN92. (Communication does not stop by changing RUN to STOP in the CPU module.)
• Turn off I/O data communication start request (Un\G17000.0).
GX Configurator-PN
The following parameters are set by GX Configurator-PN of the RJ71PN92.
Item
Description
Device Name
Set on the "Devices on the Network" window. ( Page 202 Device Name setting)
A period cannot be used at the beginning or the end. A period cannot be used
consecutively.
IP Address
Set the IP address of the NZ2FT-PN from the [General Configuration] tab of the
"NZ2FT-PN Profinet Device" window. Do not set the values out of the setting range.
Sub-Network mask
The subnet mask of the NZ2FT-PN has the same setting value as the subnet mask of
the RJ71PN92. Do not set the values out of the setting range.
Gateway IP
The gateway of the NZ2FT-PN has the same setting value as the default gateway of the
Address
RJ71PN92. Do not set the values out of the setting range.
IP address USB
Set the IP address of the USB port.
port
Process Alarm
Set it to "Disabled".
Diagnostic Alarm
Set it to "Disabled".
Type of diagnostic
Setting is not required.
alarm
Output behaviour
Set the output operation when a fieldbus error occurs. ( Page 207 Slave parameter
on fieldbus error
setting)
• All outputs off: All outputs are turned off.
• Enable substitute value: Output is produced according to the substitute value of the
output module.
• Hold last value: The output status is maintained.
Module behaviour
Set the I/O module operation during Hot swap. ( Page 207 Slave parameter setting)
on hot swap
• Continue data exchange: The operation of the output module is maintained.
• Behaviour like on fieldbus error: The output module is operated according to the
setting of "Output behaviour on fieldbus error".
Data format
Set the format of communication data. ( Page 207 Slave parameter setting)
• Motorola: Big endian
• Intel: Little endian
Setting range
Default
• Disabled
Enabled
• Enabled
• HTTP & HTTPS
HTTP &
concurrent operation
HTTPS
• only HTTPS; no HTTP
concurrent
operation
Setting range
Default
• 1 to 240 characters in
nz2ft-pn
total
• Half-width alphanumeric
characters, period,
hyphen
1.0.0.0 to 223.255.255.254
0.0.0.0
128.0.0.0 to
255.255.255.0
255.255.255.248
0.0.0.1 to 223.255.255.254
0.0.0.0
• 192.168.1.202
192.168.1.202
• 192.168.2.202
• 192.168.3.202
• 192.168.4.202
• 192.168.5.202
• Disabled
Disabled
• Enabled
• Disabled
Disabled
• Enabled
• All outputs off
All outputs off
• Enable substitute value
• Hold last value
• Continue data exchange
Continue data
• Behaviour like fieldbus
exchange
error
• Motorola
Motorola
• Intel
9 NZ2FT-PN
9.6 Parameter Setting
9
209