Digicom 2G Lift Dialer User Manual page 31

Table of Contents

Advertisement

2G Lift Dialer
DESCRIPTION
Enable technical & battery alarms
Example 5 0 1 0 1 0 #
a = external input, for example flooding sensor (pin9-10)
b = battery autonomy lower than 60'
c = battery error (recharge error, no battery, faulty battery)
d = no main power
Technical alarms: delay before sending the alarm due to
No battery/battery restore
No power/power restore
The signal of alarm/restore will be sent only if the status of "Battery Restore
Error" or "No power/Restored power"continues for the set time.
Modify password
Example *91*21010*12345#
Enable roaming calls with automatic affiliation to the GSM operator
Enable roaming calls with choice of GSM operator.
Example 2 9 2 2 2 2 0 1 #
Select language of standard messages:
comfort, alarm, welcome.
The available languages depends of software version.
Relays1 management: open gate
N.O. pin12-13
N.C. pin13-14
If the bell management is active (command 84t#) the command open gate
81# is ignored.
Relays1 management: bell management
Example 8 4 1 0 #
Relays2 management: open gate
N.O. pin15-16
N.C. pin16-17
If the law 13 management is active (command 831#) the command open
gate 82# is ignored.
Configuration
COMMAND
5 0 [abcd] #
The single values a b c d can be set to:
0 = disabled
1 = enabled
5 1 [m] #
m: from 1 to 99 minutes (default 5)
* 9 1 * [old pwd] * [new pwd] #
2 9 1 #
2 9 2 [operator code] #
4 5 * 3 4 # Spanish
4 5 * 3 9 # Italian (default)
4 5 * 4 4 # English
4 5 * 31 # Dutch
4 5 * 4 9 # German
8 1 #
8 4 [t] #
t:
0 = disabled (default 0).
From 1 to 99 seconds of bell ring
up to speakerphone is enabled.
99 = continuous bell ring up to
speakerphone code enabled.
8 2 #
3.5

Advertisement

Table of Contents
loading

This manual is also suitable for:

2g lift dialer metalbox8d57788d5798