Digicom 2G Lift Dialer User Manual page 29

Table of Contents

Advertisement

2G Lift Dialer
DESCRIPTION
Recording of alarm message
The command can be performed by local and remote phone only.
After the confirmation tone, dictate the message.
To interrupt the recording press * .
Automatically the recording stops after 20 seconds.
Example of message: "Lift alarm at company Digicom in Cardano al Campo,
via Alessandro Volta 39.
Press 3 for speakerphone, at the end 19 to reset the alarm".
Playback of alarm message
System identification (used only in calls with digital protocols: Ademco
Contact ID and Digicom)
Example 3 0 0 0 0 2 #
Date and time setting
Example 3 4 1 0 0 5 1 4 * 0 8 2 8 #
2G Lift Dialer synchronizes the date and time with the hour of the GSM
network at any power on, if supported by the operator, and after any
received SMS.
Autotest call: frequency
Example 3 5 0 3 * 0 5 0 9 #
The first autotest call will be performed after the set time, example: if the call
is set every 3 days, the first call will be made after 3 days.
For an immediate test call, se the next command.
Autotest call: test call
After this command 2G Lift Dialer make a test call right away.
This command doesn't cancel the frequency set (previous command)
Autotest call: number of attempts in case of failed call.
The attempts are made every 20 seconds. See next command.
Example 3 6 0 4 #
Autotest call: delay for the recalls
Alarm Call: delay for the recall in case of disconnection of the line without
alarm reset (19)
In case of missed call, the next attempt is made after 20 seconds.
Example 3 9 0 0 1 #
Alarm call: pause between the playback of comfort messages in case of
recall.
Alarm call: maximum time of conversation.
A few seconds before the time expires, you hear 2 beeps.
To extend the time at your disposal for other [t] minutes, digit the same code
used to enable the speakerphone. The default code is 3.
Configuration
COMMAND
4 0 #
4 1 #
3 0 [zzzz] #
3 4 [ddmmyy] * [hhmm] #
dd: day of the month from 01 to 31
mm: month from 01 to 12
yy: year from 14 (2014)
hh: hour from 00 to 23
mm: minutes from 00 to 59
3 5 [rr] * [hhmm] #
rr:
01 = every day
02 = every 2 days
03 = every 3 days
hh: hour from 00 to 23 99=random
mm: minutes from 00 to 59; 99=random
If hhmm = 9999 the 2G Lift Dialer will
calculate a random time from 00:00
to 23:59
3 5 9 9 * 0 0 0 0 #
3 6 [nn] #
nn: from 01 to 10 (default 03)
3 7 [ss] #
ss: from 01 to 99 seconds (default 20)
3 9 0 [mm] #
mm: minutes from 00 to 59 (default 02)
3 9 1 [tt] #
tt:
from 01 to 99 seconds (default 20)
3 9 2 [t] #
t:
from 1 to 9 minutes (default 3)
0 conversation active till the end
alarm reset code.