Remove and Replace the Power Supply Module

Figure 43: Remove the SSD
Step 4
To replace the SSD, make sure the power switch is still in the OFF position, and then hold the SSD in front of slot 1 and
push it in gently until it is seated.
Step 5
To install the MSP SSD, make sure the power switch is still in the OFF position and then remove the blank faceplate in
slot 2 by loosening the captive screws on either side of the faceplate.
Step 6
Hold the MSP SSD in front of slot 2 and push it in gently until it is seated.
Caution
Do not switch the two SSDs. Only the optional MSP SSD can be installed in slot 2. If you remove it and install
it in slot 1, all stored file capture data is lost.
Step 7
Tighten the captive screws on either side of the SSD.
Step 8
Verify that the SSD is operational by checking the SSD LED. See
fan LEDs.

Remove and Replace the Power Supply Module

You can remove and replace power supply modules while the system is running.
Safety Warnings
Cisco Firepower 4110, 4120, 4140, and 4150 Hardware Installation Guide
62
Take note of the following warnings:
Installation, Maintenance, and Upgrade
Front Panel LEDs, on page 9
for a description of the