2.
Disconnect the cables and harnesses.
(1) Disconnect the two fine-wire coaxial cables from the two connectors (CN6402, CN6403) on the HPR-56
board.
(2) Disconnect the harness from the connector (CN101) on the IF-1227 board.
(3) Open the clamper, and release the two fine-wire coaxial cables and the harness.
Fine-wire coaxial cable
IF-1227 board
HPR-56 board
CN6403 CN6402
Note
Pay attention to the orientations of the connectors of the two fine-wire coaxial cables and the harness.
• Contacts of the connector of the fine-wire coaxial cable are visible from one side, but are invisible from the
other side.
• The harness is visible from the gap of the connector of the harness on one side, but is invisible on the other
side.
Fine-wire coaxial cable
Side A
IF-1227 board
HPR-56 board
CN6403 CN6402
PMW-PZ1
Fine-wire coaxial cable
Clamper
CN101
Fine-wire coaxial cable
Harness
Side A
Side A
CN101
Harness
Orientation of connector
Fine-wire coaxial cable
Side A
Contacts
Harness
Side A
Side B
Side B
Harness
5-4