Honeywell SmartVFD HVAC MR4 User Manual page 105

Variable frequency drives for constant and variable torque applications
Table of Contents

Advertisement

Honeywell
• 33
3.5.3
Group 3.1: Motor settings
3.5.3.1
Basic Settings
Code
Parameter
M3.1.1.1 Motor nominal voltage
Motor nominal fre-
M3.1.1.2
quency
M3.1.1.3
Motor nominal speed
M3.1.1.4 Motor nominal current
M3.1.1.5
Motor Cos Phi
M3.1.1.6
Motor nominal power
M3.1.1.7
Motor current limit
M3.1.1.8
Supply voltage
Min
Max
Unit
Varies
Varies
V
8.00
320.00
Hz
24
19200
rpm
Varies
Varies
A
0.30
1.00
Varies
Varies
kW
Varies
Varies
A
Varies
Varies
V
Table 22. Basic motor settings
HVAC A
Default
ID
Find this value U n on the
rating plate of the motor.
This parameter sets the volt-
Varies
110
age at the field weakening
point to 100% * U nMotor .
Note also used connection
(Delta/Star).
Find this value f n on the rat-
60.00
111
ing plate of the motor.
Find this value n n on the rat-
1720
112
ing plate of the motor.
Find this value I n on the rat-
Varies
113
ing plate of the motor.
Find this value on the rating
0.80
120
plate of the motor
Find this value In on the rat-
Varies
116
ing plate of the motor.
Maximum motor current
Varies
107
from drive
Varies
1200
PPLICATION