Honeywell SMV800 User Manual page 89

Multivariable transmitter modbus communication
Hide thumbs Also See for SMV800:
Table of Contents

Advertisement

Minimum ET Limit
Minimum ET
Value
ET Dn Cnt
ET Upper Limit
ET Tracking
ET Up Time
ET Lower Limit
ET Dn Time
Temperature Module
Diagnostics – Advanced Diagnostics – Modules – Temperature Module
Key: Plain = Read only Bold = Configurable Bold underline = Method Bold italic = Table or graph
Temp Module
Install Date
Sensor Service Life
Sensor Stress Life
Temp Module
Time in Service
Temp Sensor
Time in Service
Maximum ET
Value
ET Up Cnt
ET Tracking
Minimum ET
Value
ET Dn Cnt
Revision 1.0
Communications board Electronics Temperature (ET) lowest
operating limit from specification.
Communications board Electronics Temperature (ET) lowest
measured value
The total number of minutes that the Communications board
Electronics Temperature (ET) has been below the lower stress limit
(ET Lower Limit)
High Electronics Temperature stress limit – if the Communications
board ET exceeds this limit, the ET Up Cnt and ET Up Time will be
updated. Value is equal to "Max ET Limit" minus 10% of limits
range.
Displays time since the Communications board Electronics
Temperature was last measured as exceeding the ET Upper Limit
(in minutes)
Low Electronics Temperature stress limit – if the Communications
board ET exceeds this limit, the ET Dn Cnt and ET Dn Time will be
updated. Value is equal to "Min ET Limit" plus 10% of limits range.
Displays time since the Communications board Electronics
Temperature was last measured below the ET Lower Limit (in
minutes)
The Temperature Module Installation Date
Percent of the expected Service Life that the Temperature Module
has been in service. Value is based on electronics temperature.
Service life accumulates faster at higher temperatures with an
exponential relationship.
Percent of Temperature Sensor service life spent in stressful
conditions. Indicates the % of service life where one or more of
Process Temperature, processor core temperature, or electronics
temperature are within 10% of respective range limits.
Total time that the Temperature Module has been in service. Time
based on the Temperature Module Install Date.
Total time that the Temperature Sensor has been in service Based
on the Sensor Install Date
Temperature Module Electronics Temperature (ET) highest
measured value
The total number of minutes that the Temperature Module
Electronics Temperature (ET) has exceeded the upper stress limit
Temperature Module Electronics Temperature (ET) lowest
measured value
The total number of minutes that the Temperature Module
Electronics Temperature (ET) has been below the lower stress limit
SMV800 Modbus User's Guide