Replacement Meterbody and Heads for Model STD 110
The ST 3000 Pressure Transmitter (Model STD110) is now being shipped with newly
designed meter body and process heads. If a replacement meter body is needed, it
should be ordered from the Model Number stated on the meter body nameplate. This
meter body replacement number will start with STD110S-xxx...
This new transmitter is functionally identical to previous models, with the same
specifications and intended applications (Draft Range: 10" H
The new version, which will continue as Model STD110, differs only in the physical
size and form of the meter body, process head, and associated components.
With exceptions noted in this addendum, information given in User's Manual
34-ST-25-17A applies also to this newer design.
Installation, operation, maintenance, calibration, and troubleshooting tasks remain
virtually the same as for the previous version. Differences appear primarily in torque
specifications when replacing meter bodies, and in part numbering and part
recognition when replacing components or assemblies.
This addendum provides details for parts replacement that span a variety of
applications of the Model STD110. For applicability of parts for specific options
available for the newer design of the Model STD110, refer to:
For availability and applicability of parts, refer to:
ST 3000 Smart Transmitter
Series 100 Differential Pressure Models
Specification and Model Selection Guide
34-ST-03-60
34-ST-99-20 (Addendum to 33-ST-25-17A)
34-ST-99-20
04/03
Addendum
User Manual
(to
34-ST-25-17A)
O [25 mbar]).
2
1 of 6

Advertisement

loading

Summary of Contents for Honeywell ST 3000

  • Page 1 Replacement Meterbody and Heads for Model STD 110 Overview The ST 3000 Pressure Transmitter (Model STD110) is now being shipped with newly designed meter body and process heads. If a replacement meter body is needed, it should be ordered from the Model Number stated on the meter body nameplate. This meter body replacement number will start with STD110S-xxx...
  • Page 2: Description Of Change

    Table 1 – Additions to the User Manual Page # in User Sub-Section Description of Change Manual 4 – Installation - Piping ST 3000 In Step 5, do not use the torque specification of 47.5 Transmitter to 54 N∙m (35 to 40 lb-ft). Table 13 Installing Flange...
  • Page 3 Figure 1 ST 3000 Model STD110 (Revision S or greater) 04/03 34-ST-99-20 (Addendum to 33-ST-25-17A) 3 of 6...
  • Page 4 Table 1 Parts Identification for Callouts in Figure 1 Part Number Description Qty/ Unit Specify complete Series 100 replacement meter body without heads model number from nameplate plus R300 Specify complete Series 900 replacement meter body without heads model number from nameplate plus R300 51452866-001 Bolts and Nuts Kit, Carbon Steel...
  • Page 5 Table 2 Flange Adapter Kits Quantity Part Number Description Per Unit Flange Adapter Kit, with: 51452867-110 SS Flange Adapters and with carbon steel bolts 51452867-210 SS Flange Adapters and with SS (NACE) bolts 51452867-310 SS Flange Adapters and with SS (non-NACE) bolts 51452867-410 SS Flange Adapters and with B7M alloy steel bolts 51452867-150...
  • Page 6 Table 3 Process Head Assembly Kits Description Part Number Quantity Per Unit Process Head Assembly Kit, with PTFE Gasket and with: 51452864-032 Hastelloy C head with side vent/drain 51452864-012 Carbon steel head with side vent/drain 51452864-022 Stainless steel head with side vent/drain 51452864-042 Monel head with side vent/drain 51452864-010...