Honeywell SMV800 User Manual page 68

Multivariable transmitter modbus communication
Hide thumbs Also See for SMV800:
Table of Contents

Advertisement

Flow Parameters
Refer below tables for more details regarding parameters.
Key: Plain = Read only Bold = Configurable Bold underline = Method Bold italic = Table or graph
Pipe diameter_D
Bore Diameter_d
Upper Limit Reynolds
Num_RnMin
Lower Limit Reynolds
Num_RnMax
Isentropic Coefficient_k
Discharge Exponent
Reynolds Coefficient_r1
Page 56
Flow Parameters
in
in
Upper limit for Reynolds number. Applicable
when Algorithm Options = SMV3000 Equation
Model = Dynamic
Lower limit for Reynolds number. Applicable
when Algorithm Options = SMV3000 Equation
Model = Dynamic
Isentropic Coefficient of Expansion
0.75
Applicable when Algorithm Options = SMV3000
0.5
Equation Model = Dynamic. Based on the
selected Primary element, this is auto
calculated. Coefficient of Discharge in the Flow
equation is calculated using Discharge
Exponent, Reynolds Coefficinet_r1 and
Reynolds Coefficinet_r2.
Based on the selected Primary element, this is
auto calculated. Applicable when Algorithm
Options = SMV3000 Equation Model = Dynamic
SMV800 Modbus User's Guide
Revision 1.0

Advertisement