design, 3) a variation of Code 128 that supports concatenation of neighboring
symbols, and 4) the standard layout for bar codes on a blood product label. Use the
bar codes below to turn concatenation on or off. Default =Off.
Code 128 Redundancy
If you are encountering errors when reading Code 128 bar codes, you may want to
adjust the redundancy count. Redundancy adjusts the number of times a bar code
is decoded before transmission, which may reduce the number of errors. Note that
the higher the redundancy count, the longer it will take to decode the bar code. To
adjust the redundancy, scan the Code 128 Redundancy bar code below, then scan
a redundancy count between 0 and 10 on the
page 235. Then scan the Save bar code. Default = 0.
Code 128 Message Length
Scan the bar codes below to change the message length. Refer to
Description
lengths = 0-80. Minimum Default = 0, Maximum Default = 80.
Minimum Message Length
Code 128 Append
This function allows the 8680i to append the data from several Code 128 bar codes
together before transmitting them to the host computer. When the 8680i encoun-
ters a Code 128 bar code with the append trigger character(s), it buffers Code 128
110
On
(page 94) for additional information. Minimum and Maximum
Programming Chart,
Code 128 Redundancy
* Off
beginning on
Message Length
Maximum Message Length