Cisco GS7000 Installation And Operation Manual page 69

Super high output intelligent node
Table of Contents

Advertisement

Troubleshooting
Problem
AGC does not lock
Can not control with LCS
software
Poor reverse C/N
performance
Noise on reverse path
Poor frequency response
Solution
• Verify the RF configuration settings.
• Verify the USB cable connection in LCS.
Check whether the USB cable connect correctly and refer to
High Output Intelligent Node Software Installation and Configuration Guide
see whether USB connection mode on mobile phone has been configured
correctly.
• Check if the headend performance meets system design target.
• Measure level of RF input to RPD and check if the RF input level is correct.
Look at the reverse path to determine which port(s) are noisy. Using max hold
makes it easier to see bursty noise signals.
• Ensure RF cables are connected properly.
• Ensure that the diplexers match the installed splitter.
Cisco GS7000 Super High Output Intelligent Node Installation and Operation Guide
Troubleshooting the node
Cisco GS7000 Super
to
49