Procedure
To end an activated trace recording in the drive, click on the
The trace in the drive is deactivated and the status display of the trace switches to "inactive".
6.2.2.6

Displaying the trace recording

Overview
The following describes how you can display the trace recording.
Requirements
• There is an online connection to the drive unit.
• A recorded trace is saved in the drive unit.
OR
• A measurement is in the "Measurements" system folder.
Procedure
To display the recording, proceed as follows:
1. Select a trace in the drive.
OR
In the
2. Double-click the selected trace or measurement.
3. If required, activate the icon
4. Check to ensure that the signals (
can display the signals via the shortcut menu.
The recording is displayed in the "Diagram" tab.
6.2.2.7

Saving a trace recording in the project

Overview
The following describes how you can save the trace recording in the project.
Requirements
• An online connection has been established to the drive.
• A recorded trace is saved in the drive.
• The data of the trace in the drive must of been displayed at least once in the curve diagram.
For display, the recorded data are loaded from the drive.
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2
"Measurements" system folder, select a measurement
for monitoring.
) are shown in the "Diagram" tab in the signal table. You
Diagnostics
6.2 Diagnostics via Startdrive
icon.
.