Commissioning
5.3 Creating a project offline
Automatic wiring of components
With most drive systems, the DRIVE-CLiQ connections are automatically established with the
default settings when creating a component.
Note
No automatic wiring
With an S120 drive system with a CU310-2 PN, the components are not automatically wired via
DRIVE-CLiQ. In this case, you must create the DRIVE-CLiQ wiring manually.
Adapt the offline configuration
When a component is created in the offline project, the DRIVE-CLiQ connections are created
according to the default settings in Startdrive. Here, the wiring of the component in the offline
configuration must correspond to the actual wiring in your drive system.
If the DRIVE-CLiQ wiring in the offline project deviates from the the actual wiring, you must
manually correct the connections in the device view. The device view provides the following
editing options for this:
• Deleting a DRIVE-CLiQ connection
• Creating a DRIVE-CLiQ connection
The editing options are shown below using an infeed unit as example and are the same for all
of the components in the device configuration.
Deleting a DRIVE-CLiQ connection
Delete a DRIVE-CLiQ connection if you no longer require it.
1. Right click on the DRIVE-CLiQ connection.
A shortcut menu is opened.
2. To remove the DRIVE-CLiQ component, select "Delete" from the shortcut menu.
The DRIVE-CLiQ connection is deleted.
118
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2