Diagnostics

6.1 Diagnostics using LEDs

6.1
Diagnostics using LEDs
Table 6-1
6.1.1

Control Units

6.1.1.1

LED states of a CU310-2 PN

There are four LEDs on the front of the CU310-2 housing.
Table 6-2
RDY
COM
OUT > 5V
MOD
The various LEDs are switched either on or off as the Control Unit powers up (depending on the
phase that the system is currently in). When switched on, the color of the LEDs shows the status
of the corresponding power-up phase.
In the event of a fault, power up will be ended in the corresponding phase. The LEDs that are
switched on retain their colors so that the fault can be determined on the basis of the
combination of the color LEDs that are lit and unlit.
All the LEDs go out briefly if the CU310-2 has ramped up without error. The system is ready for
operation when the LED "RDY" is permanently green.
282
Appearance of the LEDs for the display of the operating states
LED is on.
(Steady light)
Possible colors: Red, green, orange or yellow.
LED is off.
Is partly indicated by hyphens in the following tables in the "Color" column.
LED flashes slowly.
(Flashing light 0.5 Hz)
LED flashes quickly.
(Flashing light 2 Hz)
LED flashes with variable frequency.
(Flashing light)
LED flashes slowly alternately in two different colors (for example red/green).
(Flashing light 0.5 Hz)
LED flashes quickly alternately in two different colors (for example red/green).
(Flashing light 2 Hz)
LEDs
Ready
Option Board
Encoder current supply > 5 V (TTL/HTL)
Operating mode (reserved)
Commissioning with Startdrive
Commissioning Manual, 06/2020, 6SL3097-5AA10-0BP2