Step 3: Evaluating Recordings - Siemens SIPROTEC 5 Manual

Fault recorder, v7.50 and higher
Hide thumbs Also See for SIPROTEC 5:
Table of Contents

Advertisement

[sctrigge-280113-01.tif, 1, en_US]
Figure 7-13
Routing the Signals and Indications in the Information Routing
You can find a detailed description of the routings in chapter
Rout signals, indications, etc. with the Information routing to sources and goals.
²
The Information routing is a device-oriented tool. A separate Information routing is available for each
offline configuration present in a project.
Routing the Measured Values in the Information Routing
You can find more information about the measured values that can be routed as well as recommenda-
²
tions in chapter

Step 3: Evaluating Recordings

7.1.4
Generating the Record by the Device
The records generated by the fault recorder can be loaded and converted by DIGSI 5 or SICAM PQS. A
maximum of 3 communication connections are possible, irrespective of the type of DIGSI 5 or IEC 61850.
Depending on the recorder, the records are provided in different file formats (see the following table).
Table 7-2
Interface
DIGSI 5
IEC 61850
IEC 61850
6
FSR: Fast-Scan Recorder
7
SSR: Slow-Scan Recorder
8
CR: Continuous recorder
9
TR: Trend recorder
SIPROTEC 5, Fault Recorder, Manual
C53000-G5040-C018-5, Edition 11.2017
Trigger Routing in the Recorder Interaction Matrix
7.6.1.2 Using Measurands
File Formats Used by the Individual Recorders
File Format
SIPROTEC 5
SIPROTEC 5
COMTRADE
7.2.3 Function
.
FSR
6
X
X
X
Fault Recorder
7.1 Introduction to DIGSI 5
Description.
SSR
7
CR
8
TR
9
X
X
X
X
X
225