Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual page 462

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

Configuring Redundant Site Controller
Procedure 15-8 Configure Ethernet Ports (Continued)
6
7
8
Procedure 15-9 Configure Site Controller IDs
1
2
3
4
15-32
From the prompt, run the command spw inet/if/eth0 "dhcp:no
addr:10.0.253.X mask:255.255.255.0 dev_name:tsec dev_unit:0
ethaddr:yy:yy:yy:yy:yy:yy mtu:1500"
From the prompt, run the command spw inet/if/eth1 "dhcp:no
addr:10.0.254.X mask:255.255.255.0 dev_name:tsec1 dev_unit:1
ethaddr:yy:yy:yy:yy:yy:yy mtu:1500"
Remember to check the IP settings on both SCs.
For an MTS using a single Site Controller, the Ethernet settings should be checked
using the ifconfig -a command from the SC application prompt. From the
output, confirm that the eth0 and eth1 ports are configured as expected. See Procedure
below for more information on how to set SC IDs.
The Site Controllers must have different ID values configured. To check
the SC id, follow the steps below.
Log onto the Site Controller Application MMI.
From the SC: prompt, run the command id.
An id value of either A or B is displayed.
Perform the same check on the second Site Controller.
• X = 1 for SC1, and 2 for SC2
• yy:yy:yy:yy:yy:yy = the MAC address of the interface. Note that
eth0 and eth1 have different MAC addresses.
• X = 1 for SC1, and 2 for SC2
• yy:yy:yy:yy:yy:yy = the MAC address of the interface. Note that
eth0 and eth1 have different MAC addresses.
Chapter 15: Expansion Options