Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual page 394

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

Base Radio Alarms
Table 13-7 Generic Base Radio Alarms (Continued)
Alarm ID
ALM_TX_TEMP_INTER-
NAL_FAULT
ALM_PA_TEMP_INTER-
NAL_WARN
ALM_PA_TEMP_INTER-
NAL_FAULT
ALM_TX_TEMP_INTERNAL_SE-
VERE
ALM_PA_TEMP_INTERNAL_SE-
VERE
ALM_TX_DC_PS
ALM_PA_IN_RUSH_FAIL
ALM_TX_3_3V_PS
ALM_PA_3_3V_SUPPLY_FAIL
ALM_TX_5V_PS
ALM_PA_5V_SUPPLY_FAIL
13-28
Recovery
Description
Action
Internal Power
BRC is de-keyed
Amplifier
by the software.
temperature is
too high.
The same as ALM_TX_TEMP_INTERNAL_WARN
The same as ALM_TX_TEMP_INTERNAL_FAULT
Internal Power
BRC is de-keyed
Amplifier
by the software.
temperature is
too high.
The same as ALM_TX_TEMP_INTERNAL_SEVERE
Power Amplifier
BRC is de-keyed
DC supply
by the software.
failure.
The same as ALM_TX_DC_PS
Power Amplifier
BRC is de-keyed
3.3V DC supply
by the software.
failure.
Reported when ALM_TX_3_3V_PS is set and ALM_TX_DC_PS is cleared
Power Amplifier
BRC is de-keyed
5V DC supply
by the software.
failure.
Reported when ALM_TX_5V_PS is set and ALM_TX_DC_PS is cleared
Chapter 13: MTS Troubleshooting
Clear Action
If the alarm
condition
disappears the
alarm is cleared
and BRC can be
re-keyed again.
If the alarm
condition
disappears the
alarm is cleared
and BRC can be
re-keyed again.
If the alarm
The alarm may be
condition
reported because
disappears the
of some power
alarm is cleared
supply problems
and BRC can be
(cables, connectors)
re-keyed again.
or the BRC hardware
failure / configuration
problem.
If the alarm
The alarm may be
condition
reported because
disappears the
of some power
alarm is cleared
supply problems
and BRC can be
(cables, connectors)
re-keyed again.
or the BRC hardware
failure / configuration
problem.
If the alarm
The alarm may be
condition
reported because
disappears the
of some power
alarm is cleared
supply problems
and BRC can be
(cables, connectors)
re-keyed again.
or the BRC hardware
failure / configuration
problem.
6802800U74-N September 2009
Notes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dimetra mts 4

Table of Contents